{"product_id":"raychem-rpg-kamfet-class-0-electrical-insulating-gloves","title":"Raychem RPG Kamfet Class 0 Electrical Insulating Gloves","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eRaychem RPG Kamfet Class 0 Electrical Insulating Gloves | KL-B | 1000V AC\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eRaychem RPG Kamfet Class 0 Electrical Insulating Gloves (KL-B)\u003c\/strong\u003e are professional-grade \u003cstrong\u003elatex rubber electrical safety gloves\u003c\/strong\u003e designed to provide reliable dielectric protection for qualified electricians, technicians, maintenance personnel, utility workers, and industrial professionals working with electrical systems.\u003c\/p\u003e\n\u003cp\u003eManufactured from \u003cstrong\u003ehigh-quality latex rubber\u003c\/strong\u003e, these gloves feature a \u003cstrong\u003eseamless, ergonomic construction\u003c\/strong\u003e designed to provide continuous electrical insulation while maintaining flexibility and hand dexterity. The Class 0 gloves are rated for a \u003cstrong\u003emaximum working voltage of 1,000V AC and 1,500V DC\u003c\/strong\u003e, making them suitable for appropriate electrical applications within their specified ratings.\u003c\/p\u003e\n\u003cp\u003eThe gloves are \u003cstrong\u003enon-powdered and full-fingered\u003c\/strong\u003e, with an extended insulating cuff providing additional coverage around the wrist and lower arm. Their ergonomic design supports comfortable handling of electrical components, tools, panels, and equipment during suitable maintenance and servicing activities.\u003c\/p\u003e\n\u003cp\u003eAccording to the supplied product information, the gloves also feature \u003cstrong\u003eIEC 61482-1-2 Box Test, APC-2 arc-flash protection characteristics\u003c\/strong\u003e, providing an additional protective feature when used as part of a properly selected arc-flash PPE system.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Raychem RPG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e Kamfet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e KL-B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClassification:\u003c\/strong\u003e Class 0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e High-Quality Latex Rubber\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e Red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Seamless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Non-Powdered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinger Type:\u003c\/strong\u003e Full Fingered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Voltage:\u003c\/strong\u003e 1,000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Use Voltage:\u003c\/strong\u003e 1,500V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc Flash Protection:\u003c\/strong\u003e IEC 61482-1-2, Box Test, APC-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Standards:\u003c\/strong\u003e EN 60903:2003 \/ IEC 60903:2014\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCuff:\u003c\/strong\u003e Extended Electrical-Insulating Cuff\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGender:\u003c\/strong\u003e Unisex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 Pair\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Made in India\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Plastic Poly Bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSuperior Electrical Insulation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eClass 0 latex rubber construction\u003c\/strong\u003e is designed to provide a continuous insulating barrier for suitable electrical work. The seamless design eliminates stitched construction through the insulating portion, while the ergonomic shape supports flexibility and comfortable hand movement.\u003c\/p\u003e\n\u003cp\u003eThe extended cuff provides additional wrist and lower-arm coverage, making these gloves suitable for use as part of a complete electrical PPE system. They are designed for professional applications where appropriate electrical insulation and hand dexterity are required.\u003c\/p\u003e\n\u003ch3\u003eArc Flash Protection\u003c\/h3\u003e\n\u003cp\u003eThe supplied product information specifies \u003cstrong\u003eIEC 61482-1-2 Box Test, APC-2\u003c\/strong\u003e arc-flash protection. Arc-flash protection and electrical insulation are separate protective characteristics, so complete PPE should always be selected according to the specific electrical and arc-flash hazards present at the worksite.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eRaychem RPG Kamfet Class 0 gloves are suitable for qualified professionals involved in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical maintenance and repair\u003c\/li\u003e\n\u003cli\u003eElectrical panel and switchgear maintenance\u003c\/li\u003e\n\u003cli\u003eIndustrial electrical maintenance\u003c\/li\u003e\n\u003cli\u003eElectrical installation and servicing\u003c\/li\u003e\n\u003cli\u003eControl panels and machinery maintenance\u003c\/li\u003e\n\u003cli\u003ePower distribution applications\u003c\/li\u003e\n\u003cli\u003eElectrical testing and troubleshooting\u003c\/li\u003e\n\u003cli\u003eUtility and infrastructure maintenance\u003c\/li\u003e\n\u003cli\u003eIndustrial plants and workshops\u003c\/li\u003e\n\u003cli\u003eElectrical equipment inspection and servicing\u003c\/li\u003e\n\u003cli\u003eLow- and medium-voltage electrical systems within rated limits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eRaychem RPG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eKamfet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKL-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass\u003c\/td\u003e\n\u003ctd\u003eClass 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eLatex Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eSeamless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eNon-Powdered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinger Type\u003c\/td\u003e\n\u003ctd\u003eFull Fingered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Voltage\u003c\/td\u003e\n\u003ctd\u003e1,000V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Use Voltage\u003c\/td\u003e\n\u003ctd\u003e1,500V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Flash Protection\u003c\/td\u003e\n\u003ctd\u003eIEC 61482-1-2, APC-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60903:2003 \/ IEC 60903:2014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuff\u003c\/td\u003e\n\u003ctd\u003eExtended Insulating Cuff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1 Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in India\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy Choose Raychem RPG Kamfet Class 0 Gloves?\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eRaychem RPG Kamfet KL-B Class 0 gloves\u003c\/strong\u003e combine latex rubber insulation, seamless construction, ergonomic design, flexibility, extended cuff coverage, and specified arc-flash protection characteristics. They are designed to form an important part of an electrician's PPE system when working within the applicable voltage, environmental, and safety limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Safety Note:\u003c\/strong\u003e Electrical insulating gloves are safety-critical PPE. Inspect gloves carefully before every use and follow the manufacturer's requirements for inspection, cleaning, storage, electrical re-testing, and service life. Use only within the applicable voltage rating and workplace safety procedures. Electrical insulating gloves are not a substitute for de-energization, isolation, grounding, or other required electrical safety controls.\u003c\/p\u003e","brand":"raychem","offers":[{"title":"Default Title","offer_id":48235405410540,"sku":"raychem","price":1999.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/6686\/7436\/files\/Raychem_RPG_Kamfet_Class_0_Electrical_Insulating_Gloves.jpg?v=1787827263","url":"https:\/\/vajraastra.com\/products\/raychem-rpg-kamfet-class-0-electrical-insulating-gloves","provider":"Vajraastra","version":"1.0","type":"link"}