{"product_id":"raychem-kamfet-class-00-electrical-insulating-gloves","title":"Raychem Kamfet Class 00 Electrical Insulating Gloves","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eRaychem Kamfet Class 00 Electrical Gloves | 500V AC Latex Insulating Gloves\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eRaychem Kamfet Class 00 Electrical Gloves\u003c\/strong\u003e are high-quality \u003cstrong\u003elatex rubber insulating gloves\u003c\/strong\u003e designed to provide reliable electrical insulation for qualified electricians, technicians, engineers, and maintenance professionals working on suitable low-voltage electrical systems.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003emaximum working voltage of 500V AC\u003c\/strong\u003e and \u003cstrong\u003e750V DC\u003c\/strong\u003e, these Class 00 electrical gloves are designed for appropriate electrical maintenance, testing, repair, installation, and live-working applications within their rated limits. Their \u003cstrong\u003eseamless construction\u003c\/strong\u003e provides continuous insulating coverage while maintaining flexibility and hand dexterity for handling electrical components and tools.\u003c\/p\u003e\n\u003cp\u003eThe gloves are indicated as compliant with \u003cstrong\u003eEN 60903 and IEC 60903\u003c\/strong\u003e electrical insulating glove standards. The supplied product information also indicates \u003cstrong\u003eIEC 61482-1-2 Box Test, APC-2 arc-flash protection\u003c\/strong\u003e; applicable certification and documentation should be verified for the specific product, model, and batch.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct:\u003c\/strong\u003e Raychem Kamfet Class 00 Electrical Gloves\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClassification:\u003c\/strong\u003e Class 00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Working Voltage:\u003c\/strong\u003e 500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Use Voltage:\u003c\/strong\u003e 750V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProof Test Voltage:\u003c\/strong\u003e 2,500V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e 5,000V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e High-Quality Latex Rubber\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Seamless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColour:\u003c\/strong\u003e Red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinger Type:\u003c\/strong\u003e Full Fingered\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approximately 300 g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity:\u003c\/strong\u003e 1 Pair\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e EN 60903 \/ IEC 60903\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArc Flash:\u003c\/strong\u003e IEC 61482-1-2 Box Test, APC-2*\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e India\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReliable Electrical Insulation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eClass 00 latex rubber construction\u003c\/strong\u003e provides electrical insulation for suitable low-voltage applications. The seamless molded design provides consistent coverage without stitched seams, while the flexible material allows comfortable hand movement and improved dexterity when performing electrical tasks.\u003c\/p\u003e\n\u003cp\u003eThese gloves are designed to be used as part of a \u003cstrong\u003eproperly selected electrical PPE system\u003c\/strong\u003e and in accordance with applicable electrical safety procedures.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eRaychem Kamfet Class 00 electrical insulating gloves are suitable for qualified professionals involved in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical maintenance and repair\u003c\/li\u003e\n\u003cli\u003eLow-voltage wiring and installation\u003c\/li\u003e\n\u003cli\u003eElectrical panels and control systems\u003c\/li\u003e\n\u003cli\u003eCircuit testing and troubleshooting\u003c\/li\u003e\n\u003cli\u003eIndustrial machinery maintenance\u003c\/li\u003e\n\u003cli\u003eElectrical equipment servicing\u003c\/li\u003e\n\u003cli\u003eUtility and power distribution work within rated limits\u003c\/li\u003e\n\u003cli\u003eBattery and DC electrical systems\u003c\/li\u003e\n\u003cli\u003eSolar and renewable-energy electrical maintenance\u003c\/li\u003e\n\u003cli\u003eConstruction-site electrical work\u003c\/li\u003e\n\u003cli\u003eElectrical testing and measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eRaychem Kamfet Class 00 Electrical Gloves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass\u003c\/td\u003e\n\u003ctd\u003eClass 00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Working Voltage\u003c\/td\u003e\n\u003ctd\u003e500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Use Voltage\u003c\/td\u003e\n\u003ctd\u003e750V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProof Test Voltage\u003c\/td\u003e\n\u003ctd\u003e2,500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstand Voltage\u003c\/td\u003e\n\u003ctd\u003e5,000V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eLatex Rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eSeamless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColour\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinger Type\u003c\/td\u003e\n\u003ctd\u003eFull Fingered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1 Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN 60903 \/ IEC 60903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Flash Rating\u003c\/td\u003e\n\u003ctd\u003eIEC 61482-1-2 Box Test, APC-2*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eIndia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhy Choose Raychem Kamfet Class 00 Gloves?\u003c\/h3\u003e\n\u003cp\u003eThese \u003cstrong\u003e500V AC electrical insulating gloves\u003c\/strong\u003e combine dielectric insulation, seamless latex rubber construction, flexibility, and ergonomic handling for suitable low-voltage electrical applications. They are a practical component of electrical PPE for professionals working around energized electrical equipment within the glove's specified ratings.\u003c\/p\u003e\n\u003cp\u003e*Arc-flash performance is stated as indicated in the supplied product information. Verify the applicable certification and documentation for the specific glove model and batch before purchase or use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Safety Note:\u003c\/strong\u003e Electrical insulating gloves are safety-critical PPE. Always inspect gloves before use and follow the manufacturer's instructions for inspection, storage, cleaning, handling, and periodic electrical re-testing. Select gloves based on the actual electrical hazard, voltage, working conditions, and applicable safety regulations. \u003cstrong\u003eDo not use Class 00 gloves above their rated voltage limits.\u003c\/strong\u003e\u003c\/p\u003e","brand":"raychem","offers":[{"title":"Default Title","offer_id":48235401969900,"sku":"ray","price":1599.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0816\/6686\/7436\/files\/31ptMkiHceL.jpg?v=1787826971","url":"https:\/\/vajraastra.com\/products\/raychem-kamfet-class-00-electrical-insulating-gloves","provider":"Vajraastra","version":"1.0","type":"link"}